| Electrical data |
| Power supply type : |
Direct current |
| Working voltage [V]: |
10 ÷ 55 |
| Current consumption [mA]: |
< 10 mA @ 24Vdc |
| Protection class : |
III |
| Reverse polarity protection : |
Presente |
| Outputs |
| Electrical design : |
PNP |
| Function : |
NO+NC |
| Max voltage drop [V]: |
< 1.8 |
| Max output current [mA]: |
200 |
| Max switching frequency [Hz]: |
300 |
| Short circuit protection : |
Present |
| Overload protection : |
Present |
| Detection zone |
| Switching distance-Sn [mm]: |
20 |
| Real sensing distance-Sr [mm]: |
20 ±10% |
| Operative distance-So [mm]: |
0 ÷ 16.20 |
| Accuracy and Deviations |
| Correction factor : |
Stainless steel: 0.9 - Brass: 0.5 - Aluminium: 0.4 - Copper: 0.4 |
| Hysteresis [%Sr]: |
< 10 |
| Switching point drift [%Sr]: |
-1 |
| Repeatability [%Sn]: |
< 3 |
| Environmental conditions |
| Temperature limits [°C]: |
-25°C ÷ +70°C |
| IP rating : |
IP65 |
| Display and control elements |
| Display : |
Output switching status - 1 x LED: Yellow |
| Mechanical data |
| Housing : |
Parallelepiped |
| Dimensions [mm]: |
40 x 40 x 114 |
| Materials : |
Housing: PC red - Sensing area: PC red |
| Mounting : |
Not embeddable |
| Weigth [g]: |
200 |
| Electrical connection |
| Terminal block : |
4-pole terminal block |
| Compliance to Standards / Directives |
| Directives compliance : |
2014/30/EU -Electromagnetic compatibility directive (EMC) |
| Standards compliance : |
EN60947-5-2 - Product standard |